 Data Sheet
M-FIAM9
Features
* EMI filtering-MIL-STD-461E * Transient protection-MIL-STD-704A/E/F, MIL-STD-1275A/B/D * Environments-MIL-STD-810, MIL-STD-202 * Environmental stress screening * Low profile mounting options * Output power up to 500 W * Output current up to 18 A * Mini sized package * Inrush current limiting
Military COTS 28 Vin Filter Input Attenuator Module
Model Number: M-FIAM9M21*
Shown actual size: 2.28 x 2.2 x 0.5 in 57,9 x 55,9 x 12,7 mm
Product Highlights
The M-FIAM9 is a DC front-end module that provides EMI filtering and transient protection. The M-FIAM9 enables designers using Vicor's Maxi, Mini, Micro Series 24 V & Maxi Series 28 V DC-DC converters to meet conducted emission / conducted susceptibility per MIL-STD-461E; and input transients per MIL-STD-704A/E/F and MILSTD-1275A/B/D. The M-FIAM9 accepts an input voltage of 10 - 36 Vdc and delivers output power up to 500 W. M-FIAM9 is housed in an industry standard "half brick" module measuring 2.28" x 2.2" x 0.5" and depending upon model selected, may be mounted onboard or inboard for height critical applications.
Absolute Maximum Rating
Parameter +In to -In Mounting torque Pin soldering temperature Rating 36 100 5 (0.57) 500 (260) 750 (390) Unit Vdc Vdc in-lbs F(C) F(C) Notes Continuous See Fig.1 6 each, #4-40 or M3 <5 sec; wave solder <7 sec; hand solder
Thermal Resistance and Capacity
Parameter Baseplate to sink flat, greased surface with thermal pad (P/N 20264) Baseplate to ambient Free convection 1000 LFM Min Typ 0.16 0.1 7.9 2.2 Max Unit C/Watt C/Watt C/Watt C/Watt
Compatible Products
* Maxi, Mini, Micro Series 24 V Input DC-DC converters * Maxi Series 28 V Input DC-DC converters
MVA-FIAM9: A coldplate and connector option.
MTBF per MIL-HDBK-217F (M-FIAM9M21)
Temperature 25C 50C 65C Environment Ground Benign: G.B. Naval Sheltered: N.S. Airborne Inhabited Cargo: A.I.C. MTBF 3,582 644 505 Unit 1,000 Hrs 1,000 Hrs 1,000 Hrs
Part Numbering*
M-FIAM9
Product
M
1= 2= S= N= F= G=
2
Pin Style Short Pin Long Pin Short ModuMate* Long ModuMate* Short RoHS Long RoHS
1
Baseplate 1 = Slotted 2 = Threaded 3 = Through hole
Product Grade Temperatures (C) Grade Operating Storage H = -40 to +100 - 55 to +125 M = -55 to +100 - 65 to +125
The MVA-FIAM9 provides a coldplate and connector option for use with either 24 V input Maxi, Mini, Micro series DC-DC converters or VIPAC Arrays.
*Compatible with SurfMate and InMate socketing system. MVA-FIAM9 (Coldplate and connector option) H-Grade (-40C to +100C operation): MVA-FIAM9H, MVA-FIAM9H-C (On / Off control enabled) M-Grade (-55C to +100C operation): MVA-FIAM9M, MVA-FIAM9M-C (On / Off control enabled)
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
M-FIAM9
Rev. 2.1
Page 1 of 7
Set your site on VICOR at vicorpower.com
SPECIFICATIONS
(typical at TBP = 25C, nominal line and 75% load, unless otherwise specified)
INPUT SPECIFICATIONS
Parameter Input voltage Inrush limiting Transient immunity
Min 10
Typ 28
Max 36 0.007 100 250 70 50
Unit Vdc A/F Vdc Vdc Vdc Vdc
Notes Continuous
50 ms per MIL-STD-1275A/B/D, continuous operation 70 s per MIL-STD-1275A/B/D, continuous operation 20 ms per MIL-STD-704A, continuous operation 12.5 ms per MIL-STD-704E/F, continuous operation
OUTPUT SPECIFICATIONS
Parameter Output power Output current Efficiency Internal voltage drop External capacitance 330 1000 F 96 97 0.85 Min Typ Max 500 18 1.5 Unit W A % V 500 W, 25C baseplate See Figure 4 on page 4 50 V Notes
CONTROL PIN SPECIFICATIONS
Parameter ON/OFF control Enable (ON) Disable (OFF) Min 0.0 3.5 Typ Max 1.0 5.0 Unit Vdc Vdc Notes Referenced to - Vout 100 k internal pull up resistor
SAFETY SPECIFICATIONS
Parameter Dielectric withstand Min Typ 1,500 2,121 Max Vrms Vdc Unit Notes Input/Output to Base Input/Output to Base
EMI
Standard MIL-STD-461E Conducted emissions: Conducted susceptibility: Test Procedure CE101, CE102 CS101, CS114, CS115, CS116 Notes When using with V28 series converters a 27 H inductor is needed between the filter and converter for compliance below 30% of rated power.
GENERAL SPECIFICATIONS
Parameter Weight Warranty Min Typ Max 3.3 (94) 2 Unit Ounces (grams) Years Notes
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
M-FIAM9
Rev. 2.1
Page 2 of 7
Set your site on VICOR at vicorpower.com
SPECIFICATIONS (CONT.)
ENVIRONMENTAL QUALIFICATION
Altitude MIL-STD-810F, Method 500.4, Procedure I & II, 40,000 ft. and 70,000 ft. Operational. Explosive Atmosphere MIL-STD-810F, Method 511.4, Procedure I, Operational. Vibration MIL-STD-810F, Method 514.5, Procedure I, Category 14, Sine and Random vibration per Table 514.5C for Helicopter AH-6J Main Rotor with overall level of 5.6 G rms for 4 hours per axis. MIL-STD-810F, Method 514.5C, General Minimum Integrity Curve per Figure 514.5C-17 with overall level of 7.7 G rms for 1 hour per axis. Shock MIL-STD-810F, Method 516.5, Procedure I, Functional Shock, 40 g. MIL-S-901D, Lightweight Hammer Shock, 3 impacts / axis, 1,3,5 ft. MIL-STD-202F, Method 213B, 60 g, 9 ms half sine. MIL-STD-202F, Method 213B, 75 g, 11ms Saw Tooth Shock. Acceleration MIL-STD-810F, Method 513.5, Procedure II, table 513.5-II, Operational, 2-7 g, 6 directions. Humidity MIL-STD-810F, Method 507.4. Solder Test MIL-STD-202G, Method 208H, 8 hour aging.
ENVIRONMENTAL STRESS SCREENING
Parameter Operating temperature Storage temperature Temperature cycling* Ambient test @ 25C Power cycling burn-in Functional and parametric ATE tests Hi-Pot test Visual inspection Test data
*Temperature cycled with power off, 17C per minute rate of change.
H-Grade -40C to +100C -55C to +125C 12 cycles -65C to +100C Yes 12 hours, 29 cycles -40C and +100C Yes Yes vicorpower.com
M-Grade -55C to +100C -65C to +125C 12 cycles -65C to +100C Yes 24 hours, 58 cycles -55C and +100C Yes Yes vicorpower.com
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
M-FIAM9
Rev. 2.1
Page 3 of 7
Set your site on VICOR at vicorpower.com
Figure 1 -- Transient Immunity: M-FIAM9 output response to an input transient.
Figure 2 -- Conducted Noise; M-FIAM9 and Model V28A12M200B DC-DC converter operating at 28 Vdc, 200 W.
40
2000 1800 1600 1400
20 0
Gain (dB)
Time (ms)
-20 -40 -60 -80 -100 0.01 0.1
CM Insertion Loss DM Insertion Loss
1200 1000 800 600 400 200 0 40 50 60 70 80 90 100
1
10
Frequency (MHz)
Vin (V)
Figure 3 -- Shut down time of M-FIAM9 vs. Overvoltage
Figure 4 -- M-FIAM9 insertion loss
Note: The M-FIAM9 is shown in the on state. To disable, open the connection between ON/OFF and -Out.
4,700 pF
+IN NC
0.01 F
+OUT
+OUT NC
+IN PC
F1
Input
Transorb P/N 19180-510
M-FIAM9
EMI GND -IN
NC ON OFF -OUT
C1
0.2 F
PR -IN
Maxi, Mini, Micro 24 Vdc Input DC-DC Converter
+S SC -S -OUT
4,700 pF
0.01 F
Component Suggestions Recommended Fuse: (F1) 20 A (max), Bussmann ABC style Capacitance: (C1) 330 F (min), 1000 F (max)
Figure 5-- Transient, Surge Protection and Recommended Reverse Polarity Protection.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
M-FIAM9
Rev. 2.1
Page 4 of 7
Set your site on VICOR at vicorpower.com
MECHANICAL DRAWINGS
Module Pins
No.
1 2 3 4 5 6 7 8 9
Function
+In No Connection Ground - In - Out ON/OFF No Connection No Connection +Out
Label
+ NC EMI/GND - - ON/OFF NC NC +
Figure 6 -- Mechanical diagram
INBOARD SOLDER MOUNT SHORT PIN STYLE PCB THICKNESS 0.062 0.010 1,57 0,25 1.790** 45,47 PLATED THROUGH HOLE DIA 0.158 4,01 (7X) 0.094 0.003 2,39 0,08 0.164 0.003 4,16 0,08 ONBOARD SOLDER MOUNT LONG PIN STYLE 0.094 0.003 2,39 0,08 0.164 0.003 4,16 0,08
ALL MARKINGS THIS SURFACE
(2X)
0.06 R (4X) 1,5
1
2
3
4
ALUMINUM BASEPLATE
1.900* 48,26 48.26 1.575** 40,00
9
8
7
6
5
PINS STYLES SOLDER:TIN / LEAD HOT SOLDER DIPPED MODUMATE: GOLD PLATED COPPER RoHS: GOLD PLATED COPPER
0.400* 10,16 0.700* 17,78 1.000* 25,40 1.400* 35,56 0.003 0,08
0.43 10,9
0.53 13,5
0.195 4,95
* DENOTES TOL = ** PCB WINDOW
Figure 7 -- PCB Mounting Specifications.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
M-FIAM9
Rev. 2.1
Page 5 of 7
Set your site on VICOR at vicorpower.com
INCHES MM
1.04 26,4
1.54 39,1 Output Connector
0.31 7,8
4.7 119,4
MVA - FIAM9
Input Connector
0.81 20,6
1 11
10 20
1 10
9 18
Input Connector
Pin # 1-4 5-7 8 9 10 11 - 13 14 - 17 18 19 20 Function -Vin +Vin NC PE protective earth PE protective earth -Vin +Vin NC PE protective earth PE protective earth
Output Connector
Pin # 1 2 3 4 5 6 7 8 9 Function +Vout +Vout +Vout N/C N/C N/C -Vout -Vout -Vout Pin # 10 11 12 13 14 15 16 17 18 Function +Vout +Vout +Vout NC NC On / Off -Vout -Vout -Vout
Input Mounting Connector
Housing Pin Kit
Vicor P/N
24795 24796 24828
Output Mounting Connector
Housing Pin Kit
Vicor P/N
25050 24796 25067
Note: The MVA-FIAM9H and MVA-FIAM9M are delivered with the On / Off control already configured as On using a 0 Ohm resistor on the underside of the output connector board. The MVA-FIAM9H-C and MVA-FIAM9M-C are delivered without the 0 Ohm resistor installed, allowing for user control of the On / Off functionality.
Figure 8 -- MVA-FIAM9 Pakaging Option
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 M-FIAM9 Rev. 2.1 Page 6 of 7
Set your site on VICOR at vicorpower.com
Warranty
Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or maintenance. Vicor shall not be liable for collateral or consequential damage. This warranty is extended to the original purchaser only. EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, VICOR MAKES NO WARRANTY, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Vicor will repair or replace defective products in accordance with its own best judgement. For service under this warranty, the buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty. Information published by Vicor has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Vicor reserves the right to make changes to any products without further notice to improve reliability, function, or design. Vicor does not assume any liability arising out of the application or use of any product or circuit; neither does it convey any license under its patent rights nor the rights of others. Vicor general policy does not recommend the use of its components in life support applications wherein a failure or malfunction may directly threaten life or injury. Per Vicor Terms and Conditions of Sale, the user of Vicor components in life support applications assumes all risks of such use and indemnifies Vicor against all damages.
Vicor's comprehensive line of power solutions includes high density AC-DC and DC-DC modules and accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or malfunction could result in injury or death. All sales are subject to Vicor's Terms and Conditions of Sale, which are available upon request.
Specifications are subject to change without notice. Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the products described in this data sheet. Interested parties should contact Vicor's Intellectual Property Department.
Vicor Corporation 25 Frontage Road Andover, MA, USA 01810 Tel: 800-735-6200 Fax: 978-475-6715 email Customer Service: custserv@vicorpower.com Technical Support: apps@vicorpower.com
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
M-FIAM9
Rev. 2.1
7/09
Set your site on VICOR at vicorpower.com


▲Up To Search▲   

 
Price & Availability of M-FIAM9H11

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X